schneider-electric modicon_m340_bmxp341000_firmware 特权管理不恰当
CVE编号
CVE-2022-0222利用情况
暂无补丁情况
N/A披露时间
2022-11-22漏洞描述
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24)解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
|---|---|
| https://www.se.com/us/en/download/document/SEVD-2022-102-02/ |
受影响软件情况
| # | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
| 1 | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxnoe0100_firmware | - | - | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxnoe0110h_firmware | - | - | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxnoe0110_firmware | - | - | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxnor0200h_firmware | - | - | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp341000_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342000_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp3420102_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342010_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342020h_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342020_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp3420302h_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp3420302_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342030h_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 系统 | schneider-electric | modicon_m340_bmxp342030_firmware | * | Up to (excluding) 3.50 | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxnoe0100 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxnoe0110 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxnoe0110h | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxnor0200h | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp341000 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342000 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342010 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp3420102 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342020 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342020h | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342030 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp3420302 | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp3420302h | - | - | |||||
| 运行在以下环境 | |||||||||
| 硬件 | schneider-electric | modicon_m340_bmxp342030h | - | - | |||||
- 攻击路径 网络
- 攻击复杂度 低
- 权限要求 无
- 影响范围 未更改
- 用户交互 无
- 可用性 高
- 保密性 无
- 完整性 无
| CWE-ID | 漏洞类型 |
| CWE-269 | 特权管理不恰当 |
Exp相关链接
版权声明
本站原创文章转载请注明文章出处及链接,谢谢合作!








评论