CVE-2022-45138漏洞
CVE编号
CVE-2022-45138利用情况
暂无补丁情况
N/A披露时间
2023-02-27漏洞描述
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
---|---|
https://cert.vde.com/en/advisories/VDE-2022-060/ |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
系统 | wago | 751-9301_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | 751-9301_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | 751-9301_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | 752-8303/8000-002_firmware | * | From (including) 18 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | 752-8303/8000-002_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | 752-8303/8000-002_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | pfc100_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | pfc100_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | pfc100_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | pfc200_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | pfc200_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | pfc200_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_advanced_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_advanced_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_advanced_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_marine_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_marine_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_marine_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_standard_firmware | * | From (including) 16 | Up to (excluding) 22 | ||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_standard_firmware | 22 | - | |||||
运行在以下环境 | |||||||||
系统 | wago | touch_panel_600_standard_firmware | 23 | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | 751-9301 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | 752-8303/8000-002 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | pfc100 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | pfc200 | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | touch_panel_600_advanced | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | touch_panel_600_marine | - | - | |||||
运行在以下环境 | |||||||||
硬件 | wago | touch_panel_600_standard | - | - | |||||
- 攻击路径 网络
- 攻击复杂度 低
- 权限要求 无
- 影响范围 未更改
- 用户交互 无
- 可用性 高
- 保密性 高
- 完整性 高
CWE-ID | 漏洞类型 |
CWE-306 | 关键功能的认证机制缺失 |