netgear m4200-10mg-poe+_firmware os命令中使用的特殊元素转义处理不恰当(os命令注入)
CVE编号
CVE-2017-18858利用情况
暂无补丁情况
N/A披露时间
2020-04-29漏洞描述
Certain NETGEAR devices are affected by command execution. This affects M4200-10MG-POE+ 12.0.2.11 and earlier, M4300-28G 12.0.2.11 and earlier, M4300-52G 12.0.2.11 and earlier, M4300-28G-POE+ 12.0.2.11 and earlier, M4300-52G-POE+ 12.0.2.11 and earlier, M4300-8X8F 12.0.2.11 and earlier, M4300-12X12F 12.0.2.11 and earlier, M4300-24X24F 12.0.2.11 and earlier, M4300-24X 12.0.2.11 and earlier, and M4300-48X 12.0.2.11 and earlier.解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
---|---|
https://kb.netgear.com/000038655/Security-Advisory-for-Unauthenticated-Remote... |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
系统 | netgear | m4200-10mg-poe+_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-12x12f_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-24x24f_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-24x_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-28g-poe+_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-28g_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-48x_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-52g-poe+_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-52g_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
系统 | netgear | m4300-8x8f_firmware | * | Up to (including) 12.0.2.11 | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4200-10mg-poe+ | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-12x12f | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-24x | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-24x24f | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-28g | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-28g-poe+ | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-48x | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-52g | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-52g-poe+ | - | - | |||||
运行在以下环境 | |||||||||
硬件 | netgear | m4300-8x8f | - | - | |||||
- 攻击路径 网络
- 攻击复杂度 低
- 权限要求 无
- 影响范围 未更改
- 用户交互 无
- 可用性 高
- 保密性 高
- 完整性 高
CWE-ID | 漏洞类型 |
CWE-78 | OS命令中使用的特殊元素转义处理不恰当(OS命令注入) |
Exp相关链接

版权声明
本站原创文章转载请注明文章出处及链接,谢谢合作!