中危 pengutronix rauc 检查时间与使用时间(toctou)的竞争条件
CVE编号
CVE-2020-25860利用情况
POC 已公开补丁情况
官方补丁披露时间
2020-12-22漏洞描述
The install.c module in the Pengutronix RAUC update client prior to version 1.5 has a Time-of-Check Time-of-Use vulnerability, where signature verification on an update file takes place before the file is reopened for installation. An attacker who can modify the update file just before it is reopened can install arbitrary code on the device.解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
---|---|
https://github.com/rauc/rauc/security/advisories/GHSA-cgf3-h62j-w9vv | |
https://www.vdoo.com/blog/cve-2020-25860-significant-vulnerability-discovered... |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
应用 | pengutronix | rauc | * | Up to (excluding) 1.5 | |||||
运行在以下环境 | |||||||||
系统 | debian_11 | rauc | * | Up to (excluding) 1.5-1 | |||||
运行在以下环境 | |||||||||
系统 | debian_12 | rauc | * | Up to (excluding) 1.5-1 | |||||
运行在以下环境 | |||||||||
系统 | debian_sid | rauc | * | Up to (excluding) 1.5-1 |
- 攻击路径 本地
- 攻击复杂度 困难
- 权限要求 普通权限
- 影响范围 有限影响
- EXP成熟度 POC 已公开
- 补丁情况 官方补丁
- 数据保密性 无影响
- 数据完整性 无影响
- 服务器危害 无影响
- 全网数量 N/A
CWE-ID | 漏洞类型 |
CWE-367 | 检查时间与使用时间(TOCTOU)的竞争条件 |
Exp相关链接
- avd.aliyun.com
版权声明
本站原创文章转载请注明文章出处及链接,谢谢合作!